148 research outputs found

    Genome-wide estimation of gender differences in the gene expression of human livers: Statistical design and analysis

    Get PDF
    BACKGROUND: Gender differences in gene expression were estimated in liver samples from 9 males and 9 females. The study tested 31,110 genes for a gender difference using a design that adjusted for sources of variation associated with cDNA arrays, normalization, hybridizations and processing conditions. RESULTS: The genes were split into 2,800 that were clearly expressed (expressed genes) and 28,310 that had expression levels in the background range (not expressed genes). The distribution of p-values from the 'not expressed' group was consistent with no gender differences. The distribution of p-values from the 'expressed' group suggested that 8 % of these genes differed by gender, but the estimated fold-changes (expression in males / expression in females) were small. The largest observed fold-change was 1.55. The 95 % confidence bounds on the estimated fold-changes were less than 1.4 fold for 79.3 %, and few (1.1%) exceed 2-fold. CONCLUSION: Observed gender differences in gene expression were small. When selecting genes with gender differences based upon their p-values, false discovery rates exceed 80 % for any set of genes, essentially making it impossible to identify any specific genes with a gender difference

    Microarray scanner calibration curves: characteristics and implications

    Get PDF
    BACKGROUND: Microarray-based measurement of mRNA abundance assumes a linear relationship between the fluorescence intensity and the dye concentration. In reality, however, the calibration curve can be nonlinear. RESULTS: By scanning a microarray scanner calibration slide containing known concentrations of fluorescent dyes under 18 PMT gains, we were able to evaluate the differences in calibration characteristics of Cy5 and Cy3. First, the calibration curve for the same dye under the same PMT gain is nonlinear at both the high and low intensity ends. Second, the degree of nonlinearity of the calibration curve depends on the PMT gain. Third, the two PMTs (for Cy5 and Cy3) behave differently even under the same gain. Fourth, the background intensity for the Cy3 channel is higher than that for the Cy5 channel. The impact of such characteristics on the accuracy and reproducibility of measured mRNA abundance and the calculated ratios was demonstrated. Combined with simulation results, we provided explanations to the existence of ratio underestimation, intensity-dependence of ratio bias, and anti-correlation of ratios in dye-swap replicates. We further demonstrated that although Lowess normalization effectively eliminates the intensity-dependence of ratio bias, the systematic deviation from true ratios largely remained. A method of calculating ratios based on concentrations estimated from the calibration curves was proposed for correcting ratio bias. CONCLUSION: It is preferable to scan microarray slides at fixed, optimal gain settings under which the linearity between concentration and intensity is maximized. Although normalization methods improve reproducibility of microarray measurements, they appear less effective in improving accuracy

    A steric tethering approach enables palladium-catalysed C-H activation of primary amino alcohols.

    Get PDF
    Aliphatic primary amines are a class of chemical feedstock essential to the synthesis of higher-order nitrogen-containing molecules, commonly found in biologically active compounds and pharmaceutical agents. New methods for the construction of complex amines remain a continuous challenge to synthetic chemists. Here, we outline a general palladium-catalysed strategy for the functionalization of aliphatic C-H bonds within amino alcohols, an important class of small molecule. Central to this strategy is the temporary conversion of catalytically incompatible primary amino alcohols into hindered secondary amines that are capable of undergoing a sterically promoted palladium-catalysed C-H activation. Furthermore, a hydrogen bond between amine and catalyst intensifies interactions around the palladium and orients the aliphatic amine substituents in an ideal geometry for C-H activation. This catalytic method directly transforms simple, easily accessible amines into highly substituted, functionally concentrated and structurally diverse products, and can streamline the synthesis of biologically important amine-containing molecules.We are grateful to the Marie Curie Foundation (D.P. & J.C.), EPSRC (T.W.G.), the ERC (V.D.), and the ERC and EPSRC for Fellowships (M.J.G.). We are grateful to Adam Smalley for DFT calculations and Yohei Shimidzu for assistance with optimization of the C–H acetoxylation reaction. Mass spectrometry data was acquired at the EPSRC UK National Mass Spectrometry Facility at Swansea University. The authors declare no competing financial interests.This is the author accepted manuscript. The final version is available from NPG via http://dx.doi.org/10.1038/nchem.236

    Gamma probes and their use in tumor detection in colorectal cancer

    Get PDF
    The purpose of this article is to summarize the role of gamma probes in intraoperative tumor detection in patients with colorectal cancer (CRC), as well as provide basic information about the physical and practical characteristics of the gamma probes, and the radiopharmaceuticals used in gamma probe tumor detection. In a significant portion of these studies, radiolabeled monoclonal antibodies (Mabs), particularly 125I labeled B72.3 Mab that binds to the TAG-72 antigen, have been used to target tumor. Studies have reported that intraoperative gamma probe radioimmunodetection helps surgeons to localize primary tumor, clearly delineate its resection margins and provide immediate intraoperative staging. Studies also have emphasized the value of intraoperative gamma probe radioimmunodetection in defining the extent of tumor recurrence and finding sub-clinical occult tumors which would assure the surgeons that they have completely removed the tumor burden. However, intraoperative gamma probe radioimmunodetection has not been widely adapted among surgeons because of some constraints associated with this technique. The main difficulty with this technique is the long period of waiting time between Mab injection and surgery. The technique is also laborious and costly. In recent years, Fluorine-18-2-fluoro-2-deoxy-D-glucose (18F-FDG) use in gamma probe tumor detection surgery has renewed interest among surgeons. Preliminary studies during surgery have demonstrated that use of FDG in gamma probe tumor detection during surgery is feasible and useful
    corecore